Time Electronics 7093 Precision Loop and DualPressure Calibrator
Time Electronics 7093 Precision Loop and DualPressure Calibrator
0.00

Product Description:

The 7093 loop and pressure calibrator is a fully integrated dual channel test and calibration system. It combines an independent micro-processor based voltage and current loop calibrator with precision pressure channels for a robust field calibration solution. The 7093 can be used on-site test and calibration of both pressure and electrical process loop signals. For pressure two channels with the ranges specified on ordering are available. Standard ranges for each channel are; 0.2, 2, 5, 10, 20, 35, 70, 100, 200, 400, and 600bar. Vacuum down to -850mbar is possible on the 2bar version.

The standard model best accuracy is 0.04% of range. A high accuracy version is available with a best accuracy 0.025% of range under lab conditions.The internal precision piezo-resistive pressure transducer allows the use in either non corrosive gas or hydraulic (demineralised water or oil) liquid. Over-pressure warning is provided on the display and by an audible sounder. Pressure connections are made via Quick release or Minimess connectors located on the control panel. Quick release are fitted for pressure ranges Vacuum to 20bar and provide a convenient push-on connection to devices under test. Minimess are fitted for pressure ranges 35bar up to 600bar, and provide easy leak-proof connection via a finger tight thread.

Two rotary switches provide pressure units selection and a separate switch is used for zeroing each channel. The pressure displays comprise of two 4.5 digit, 7 segment LCD’s, with back lighting. Additionally the pressure section offers a supplementary independent 24/36V loop supply, loop current measurement as well as a continuity function for testing for pressure switches and circuit loops.

In field use input pressure for the 7093 may be generated by externally via the 7090 pneumatic (vac to 40bar), or 7095 hydraulic (0 to 700bar) hand pump. In the lab the 7193 (vac to 40bar), 7194 (vac to 100bar), and 7195 (vac to 600bar) desktop pumps are ideal for precision pressure control.

The loop calibrator section is a high accuracy integral current and voltage loop calibration instrument. This can be used for the calibration of voltage loops up to 21V and current loops up to 50mA. Three operating modes provide a fast and easy solution to process applications: Source for simulating a transmitter as well as the loop supply, Sink for simulating a transmitter with external loop power and Measure for measurement of the loop. Four 4mm terminals provide connection to the loop under test. A dot matrix LCD screen with back lighting displays loop values to 5 digits of resolution as well as user setup.

Summary of Functions

Source Mode
• User programmable ranges – any values between 0 and 50mA or 0 and 21V.
• Fixed ranges are available: 4 to 20mA, 0 to 20mA, sqrt 4 to 20mA, sqrt 0 to 20mA.
• Fine adjustment (inching) is available for precise deviation from the calibration point.
• Manual step output – five calibration points 0%, 25%, 50%, 75%, and 100%
• Automatic step output (up/down) – five cal points with programmable dwell period.
• Ramp output – programmable ramp rate (0 to 20mA/sec or 0 to 20V/sec). Programmable dwell period (0 to 1000 seconds)

Measure Mode
• Voltage and current measuring capability with 5 digit resolution.
• Ranges: 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA.
• Signal can also be measured as a % of span on ranges: 4-20mA, 0-20mA, square root 4-20mA, square root 0-20mA.
• For all measurements a Min/Max recording function is available on demand.

The 7093 is designed to maximise battery operation time by allowing the user to activate only the components required. The 2700mAh internal NiMH battery pack provides a typical of 20 hours operation when calibrating current up to a maximum of 190 hours.

Full recharge from the battery takes a maximum of 20 hours from an internal mains power supply and charger, and can operate whilst under charge. The robust resin case is weatherproof to IP66 standard and provides protection from the harsh treatment when used in the field. The 7093 is supplied complete with manual, hoses and test leads.

The 7093 pressure channel are fitted with RS-232 connection as standard to enable readback using EasyCal calibration software. With comprehensive features EasyCal can simplify and speed up calibration procedures. Easily produce calibration certificates and reports to international quality standards.

Further options include the 7198 pressure accessories kit, a carry case with adaptors, fittings, connectors, and hoses to provide a quick solution to pressure component requirement in both the field and laboratory.

Product Specification:

Pressure Section

RANGE (BAR) 0.2 VAC TO 2 5 10 20 35 70 100 200 400 600
Accuracy (% of FS) 0.1 (HA1) 0.04 (HA) 0.04 0.04 0.04 (HA) 0.04 0.04 0.04 0.1 (HA1) 0.1 0.1
Resolution (bar) 0.01mb 0.0001 0.001 0.001 0.001 0.01 0.01 0.01 0.01 0.1 0.1

Specifications are for 1 year at 23ºC ±5ºC (±2ºC on HA models). Accuracy includes linearity and long term effects. All accuracies are ±1 digit after zero is applied. For operation outside specified temperature range, apply 70ppm per °C

HA: 0.025% accuracy model available. Specify HA on order.
HA1: 0.05% accuracy model available. Specify HA on order.

Units 0.2bar = mbar, PSI, kPa, kg/cm2, cmWg
2, 5, 10 & 20bar = bar, PSI, kPa, kg/cm2, cmWg.
35bar and above = bar, PSI, MPa, kg/cm2, Atm.
Over Pressure 1.2 x range. Audio and visual warning
Fittings 20bar and below = Quick Release. 35bar and above = Minimess
Interface RS-232
 
PRESSURE SECTION – ELECTRICAL
Range Loop current measurement 0 to 200mA
Resolution 10μA
Resistance Loop load 5Ω
Accuracy 0.05% of reading ±1 digit
Loop Drive 24V or 36V switch selectable, 50mA max – isolated and with short circuit protection
Continuity Threshold: 100Ω with audio and visual warning
Terminals 4 mm industry standard terminal posts

Loop Calibrator Section

 
DC VOLTAGE SOURCE
RANGE RESOLUTION ACCURACY OUTPUT CURRENT OUTPUT RESISTANCE
0 to 21V 1mV ±0.01% of setting ±4mV 50mA < 1Ω
 
DC VOLTAGE MEASURE (0 TO ±25V, AUTO-RANGING)
RANGE RESOLUTION ACCURACY MEASURE LOAD
0 to 5V 0.1mV ±0.01% of reading ±0.4mV 10MΩ
5 to 25V 1mV ±0.01% of reading ±2mV 10MΩ
 
DC CURRENT SOURCE
RANGE RESOLUTION ACCURACY OUTPUT VOLTAGE LOOP RESISTANCE
0 to 50mA 1µA ±0.01% of setting ±2µA 22V Max 1100Ω @ 20mA max
 
DC CURRENT MEASURE (0 TO ±125MA, AUTO-RANGING)
RANGE RESOLUTION ACCURACY MEASURE LOAD
0 to 25mA 1µA ±0.01% of reading ±2µA 24.5Ω
25 to 125mA 10µA ±0.01% of reading ±20µA 24.5Ω
 
DC CURRENT SINK
RANGE RESOLUTION ACCURACY MIN EXTERNAL DRIVE MAX EXTERNAL DRIVE
0 to 50mA 1µA ±0.01% of setting ±2µA 4V 40V
Power Source Rechargeable 2700mAh NiMH batteries or mains (230V / 110v 50 / 60Hz)
Battery Life 8 – 190hrs depending upon operational requirements
Display 7 segment LCD displays with ‘Low Battery’ warning indicator
Interfaces RS-232 for pressure readback and re-calibration (software not supplied)
Case Structural resin which is weather-proof to IP66 standard
Dimensions 41 x 32 x 17.5cm / 16.1” x 12.6” x 7”
Weight 4.08kg / 10.6 lbs approx.
Supplied with 2 pressure hoses: Quick release for 20bar and below. Minimess for versions 35bar and above.
Electrical Test Lead: Twin flexible lead, terminated with 4 off 4mm gold plated plugs.
Electrical probes: 2 off low voltage probes and 2 crocodile clips. Mains power lead.
Optional Extras Pneumatic & hydraulic pumps, gauges, EasyCal software, and calibration certificates
  • Açıklama
    • Product Description:

      The 7093 loop and pressure calibrator is a fully integrated dual channel test and calibration system. It combines an independent micro-processor based voltage and current loop calibrator with precision pressure channels for a robust field calibration solution. The 7093 can be used on-site test and calibration of both pressure and electrical process loop signals. For pressure two channels with the ranges specified on ordering are available. Standard ranges for each channel are; 0.2, 2, 5, 10, 20, 35, 70, 100, 200, 400, and 600bar. Vacuum down to -850mbar is possible on the 2bar version.

      The standard model best accuracy is 0.04% of range. A high accuracy version is available with a best accuracy 0.025% of range under lab conditions.The internal precision piezo-resistive pressure transducer allows the use in either non corrosive gas or hydraulic (demineralised water or oil) liquid. Over-pressure warning is provided on the display and by an audible sounder. Pressure connections are made via Quick release or Minimess connectors located on the control panel. Quick release are fitted for pressure ranges Vacuum to 20bar and provide a convenient push-on connection to devices under test. Minimess are fitted for pressure ranges 35bar up to 600bar, and provide easy leak-proof connection via a finger tight thread.

      Two rotary switches provide pressure units selection and a separate switch is used for zeroing each channel. The pressure displays comprise of two 4.5 digit, 7 segment LCD’s, with back lighting. Additionally the pressure section offers a supplementary independent 24/36V loop supply, loop current measurement as well as a continuity function for testing for pressure switches and circuit loops.

      In field use input pressure for the 7093 may be generated by externally via the 7090 pneumatic (vac to 40bar), or 7095 hydraulic (0 to 700bar) hand pump. In the lab the 7193 (vac to 40bar), 7194 (vac to 100bar), and 7195 (vac to 600bar) desktop pumps are ideal for precision pressure control.

      The loop calibrator section is a high accuracy integral current and voltage loop calibration instrument. This can be used for the calibration of voltage loops up to 21V and current loops up to 50mA. Three operating modes provide a fast and easy solution to process applications: Source for simulating a transmitter as well as the loop supply, Sink for simulating a transmitter with external loop power and Measure for measurement of the loop. Four 4mm terminals provide connection to the loop under test. A dot matrix LCD screen with back lighting displays loop values to 5 digits of resolution as well as user setup.

      Summary of Functions

      Source Mode
      • User programmable ranges – any values between 0 and 50mA or 0 and 21V.
      • Fixed ranges are available: 4 to 20mA, 0 to 20mA, sqrt 4 to 20mA, sqrt 0 to 20mA.
      • Fine adjustment (inching) is available for precise deviation from the calibration point.
      • Manual step output – five calibration points 0%, 25%, 50%, 75%, and 100%
      • Automatic step output (up/down) – five cal points with programmable dwell period.
      • Ramp output – programmable ramp rate (0 to 20mA/sec or 0 to 20V/sec). Programmable dwell period (0 to 1000 seconds)

      Measure Mode
      • Voltage and current measuring capability with 5 digit resolution.
      • Ranges: 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA.
      • Signal can also be measured as a % of span on ranges: 4-20mA, 0-20mA, square root 4-20mA, square root 0-20mA.
      • For all measurements a Min/Max recording function is available on demand.

      The 7093 is designed to maximise battery operation time by allowing the user to activate only the components required. The 2700mAh internal NiMH battery pack provides a typical of 20 hours operation when calibrating current up to a maximum of 190 hours.

      Full recharge from the battery takes a maximum of 20 hours from an internal mains power supply and charger, and can operate whilst under charge. The robust resin case is weatherproof to IP66 standard and provides protection from the harsh treatment when used in the field. The 7093 is supplied complete with manual, hoses and test leads.

      The 7093 pressure channel are fitted with RS-232 connection as standard to enable readback using EasyCal calibration software. With comprehensive features EasyCal can simplify and speed up calibration procedures. Easily produce calibration certificates and reports to international quality standards.

      Further options include the 7198 pressure accessories kit, a carry case with adaptors, fittings, connectors, and hoses to provide a quick solution to pressure component requirement in both the field and laboratory.

      Product Specification:

      Pressure Section

      RANGE (BAR) 0.2 VAC TO 2 5 10 20 35 70 100 200 400 600
      Accuracy (% of FS) 0.1 (HA1) 0.04 (HA) 0.04 0.04 0.04 (HA) 0.04 0.04 0.04 0.1 (HA1) 0.1 0.1
      Resolution (bar) 0.01mb 0.0001 0.001 0.001 0.001 0.01 0.01 0.01 0.01 0.1 0.1

      Specifications are for 1 year at 23ºC ±5ºC (±2ºC on HA models). Accuracy includes linearity and long term effects. All accuracies are ±1 digit after zero is applied. For operation outside specified temperature range, apply 70ppm per °C

      HA: 0.025% accuracy model available. Specify HA on order.
      HA1: 0.05% accuracy model available. Specify HA on order.

      Units 0.2bar = mbar, PSI, kPa, kg/cm2, cmWg
      2, 5, 10 & 20bar = bar, PSI, kPa, kg/cm2, cmWg.
      35bar and above = bar, PSI, MPa, kg/cm2, Atm.
      Over Pressure 1.2 x range. Audio and visual warning
      Fittings 20bar and below = Quick Release. 35bar and above = Minimess
      Interface RS-232
       
      PRESSURE SECTION – ELECTRICAL
      Range Loop current measurement 0 to 200mA
      Resolution 10μA
      Resistance Loop load 5Ω
      Accuracy 0.05% of reading ±1 digit
      Loop Drive 24V or 36V switch selectable, 50mA max – isolated and with short circuit protection
      Continuity Threshold: 100Ω with audio and visual warning
      Terminals 4 mm industry standard terminal posts

      Loop Calibrator Section

       
      DC VOLTAGE SOURCE
      RANGE RESOLUTION ACCURACY OUTPUT CURRENT OUTPUT RESISTANCE
      0 to 21V 1mV ±0.01% of setting ±4mV 50mA < 1Ω
       
      DC VOLTAGE MEASURE (0 TO ±25V, AUTO-RANGING)
      RANGE RESOLUTION ACCURACY MEASURE LOAD
      0 to 5V 0.1mV ±0.01% of reading ±0.4mV 10MΩ
      5 to 25V 1mV ±0.01% of reading ±2mV 10MΩ
       
      DC CURRENT SOURCE
      RANGE RESOLUTION ACCURACY OUTPUT VOLTAGE LOOP RESISTANCE
      0 to 50mA 1µA ±0.01% of setting ±2µA 22V Max 1100Ω @ 20mA max
       
      DC CURRENT MEASURE (0 TO ±125MA, AUTO-RANGING)
      RANGE RESOLUTION ACCURACY MEASURE LOAD
      0 to 25mA 1µA ±0.01% of reading ±2µA 24.5Ω
      25 to 125mA 10µA ±0.01% of reading ±20µA 24.5Ω
       
      DC CURRENT SINK
      RANGE RESOLUTION ACCURACY MIN EXTERNAL DRIVE MAX EXTERNAL DRIVE
      0 to 50mA 1µA ±0.01% of setting ±2µA 4V 40V
      Power Source Rechargeable 2700mAh NiMH batteries or mains (230V / 110v 50 / 60Hz)
      Battery Life 8 – 190hrs depending upon operational requirements
      Display 7 segment LCD displays with ‘Low Battery’ warning indicator
      Interfaces RS-232 for pressure readback and re-calibration (software not supplied)
      Case Structural resin which is weather-proof to IP66 standard
      Dimensions 41 x 32 x 17.5cm / 16.1” x 12.6” x 7”
      Weight 4.08kg / 10.6 lbs approx.
      Supplied with 2 pressure hoses: Quick release for 20bar and below. Minimess for versions 35bar and above.
      Electrical Test Lead: Twin flexible lead, terminated with 4 off 4mm gold plated plugs.
      Electrical probes: 2 off low voltage probes and 2 crocodile clips. Mains power lead.
      Optional Extras Pneumatic & hydraulic pumps, gauges, EasyCal software, and calibration certificates