Microtest 5237
362392
Microtest 5237 Transformer Tester
Microtest 5237 Transformer Tester
0.00

Product Description:

5237  transformer tester, test frequency is 20Hz~1MHz, 20 test points. Built-in Meter mode, dual-purpose and highest efficiency. The best choice for network transformer testing. The current needs to be conducted into the network communication transformer while diagnosing if high temperature can affect the quality of coils with other existing testers. The application of the transformer tester includes power transformers and network communication transformers, etc.

  • Basic Accuracy up to 0.1%
  • Support computer software connection and advanced software editing function
  • Innovative fixture zero-setting function to successfully prevent fixture interference from affecting the accuracy of measured values due to high test voltage
  • Able to test 30 items per second under fastest test speed. Elevate productivity significantly through auto-scan function
  • Paired with a 20-pin fixture to meet the test requirements for multi-pin network communication transformer
  • Optional 100mA DC Bias / 5×38 model is equipped with Meter Mode function / Support USB interface for data storag

Product Specification:

Measurement Data

   
Frequency 20Hz-1MHz
Turn Ratio Frequency 50Hz ~ 200kHz (10Vac Max.)
Measurement Parameters Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
Basic Accuracy ±0.1% (AC  parameter :  1KHz)
Output Impedance 100Ω
Frequency trimming resolution 5digits
Frequency output accuracy ±0.01%
Point of Test 20 Points
ESR Series/Parallel
Mathematical Mode Absolute/Percentage 
Calibration Open Circuit/ Short Circuit/Load Calibration
   
Power Supply Voltage 90Vac ~ 125Vac or 190Vac ~ 250Vac
  Frequency 48Hz ~ 62Hz
Display 320*240 dot-matrix display
Interface RS-232, Handler (option), USB (option)
Flash Memory 64 sets
Operation Auto、Manual、Remote Trigger
Environment Temperature : 10 ~ 40℃     Humidity : 10% ~ 90%
Dimension (W*H*D) 360x133x420 (mm)
Weight 9 (Kg)

Parameters Measurement Ranges

       
Parameter Range Basic Accuracy
(AC  parameter :  1KHz)
 speed
L, LK 0.1nH ~ 9999.99H  0.1%  75ms
C 0.00001pF ~ 999.99mF  0.1%  75ms
Q,D 0.00001 ~ 99999  0.0005  75ms
Z,X,R 0.00001Ω ~ 99.9999MΩ  0.1%  75ms
Y 0.01nS ~ 99.9999S  0.1%  75ms
θ -180°~ +180°  0.03°  75ms
DCR 0.01mΩ ~ 99.999MΩ  0.1%  25ms
Turn 0.01 ~ 99999.99turns  0.5%  75ms
Pin-Short 12 pairs, between pin to pin  —  25ms

Applications

Power transformer, Network communication transformer

  • Açıklama
    • Product Description:

      5237  transformer tester, test frequency is 20Hz~1MHz, 20 test points. Built-in Meter mode, dual-purpose and highest efficiency. The best choice for network transformer testing. The current needs to be conducted into the network communication transformer while diagnosing if high temperature can affect the quality of coils with other existing testers. The application of the transformer tester includes power transformers and network communication transformers, etc.

      • Basic Accuracy up to 0.1%
      • Support computer software connection and advanced software editing function
      • Innovative fixture zero-setting function to successfully prevent fixture interference from affecting the accuracy of measured values due to high test voltage
      • Able to test 30 items per second under fastest test speed. Elevate productivity significantly through auto-scan function
      • Paired with a 20-pin fixture to meet the test requirements for multi-pin network communication transformer
      • Optional 100mA DC Bias / 5×38 model is equipped with Meter Mode function / Support USB interface for data storag

      Product Specification:

      Measurement Data

         
      Frequency 20Hz-1MHz
      Turn Ratio Frequency 50Hz ~ 200kHz (10Vac Max.)
      Measurement Parameters Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
      Basic Accuracy ±0.1% (AC  parameter :  1KHz)
      Output Impedance 100Ω
      Frequency trimming resolution 5digits
      Frequency output accuracy ±0.01%
      Point of Test 20 Points
      ESR Series/Parallel
      Mathematical Mode Absolute/Percentage 
      Calibration Open Circuit/ Short Circuit/Load Calibration
         
      Power Supply Voltage 90Vac ~ 125Vac or 190Vac ~ 250Vac
        Frequency 48Hz ~ 62Hz
      Display 320*240 dot-matrix display
      Interface RS-232, Handler (option), USB (option)
      Flash Memory 64 sets
      Operation Auto、Manual、Remote Trigger
      Environment Temperature : 10 ~ 40℃     Humidity : 10% ~ 90%
      Dimension (W*H*D) 360x133x420 (mm)
      Weight 9 (Kg)

      Parameters Measurement Ranges

             
      Parameter Range Basic Accuracy
      (AC  parameter :  1KHz)
       speed
      L, LK 0.1nH ~ 9999.99H  0.1%  75ms
      C 0.00001pF ~ 999.99mF  0.1%  75ms
      Q,D 0.00001 ~ 99999  0.0005  75ms
      Z,X,R 0.00001Ω ~ 99.9999MΩ  0.1%  75ms
      Y 0.01nS ~ 99.9999S  0.1%  75ms
      θ -180°~ +180°  0.03°  75ms
      DCR 0.01mΩ ~ 99.999MΩ  0.1%  25ms
      Turn 0.01 ~ 99999.99turns  0.5%  75ms
      Pin-Short 12 pairs, between pin to pin  —  25ms

      Applications

      Power transformer, Network communication transformer

Kapat