5045 Oscilloscope
362517
5045 Oscilloscope Calibrator
5045 Oscilloscope Calibrator
0.00

Product Description:

Quick and Easy Oscilloscope Calibration to 600MHz
The 5045 is a versatile, high accuracy calibrator capable of calibrating digital and analogue oscilloscopes, timer/counters, and frequency meters.
It provides a wide range of outputs for amplitude, frequency, period and bandwidth. Amplitude calibration is achieved by a DC signal or 1kHz square-wave, ranging from 1mV to 220V (2V max for 50 ohm loads). Deviation up to ±9.99% allows fine adjustment of amplitude and direct readout of error.
Accurate frequencies are generated from a temperature controlled quartz crystal oscillator. Alternatively a 10MHz reference input in can be used. Timing accuracy of 0.1ppm is suitable for most oscilloscopes and timer counters. A precise square-wave output provides a fast rise time of less than 300ps, which allows bandwidth testing up to 600MHz.

Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/-9.99%). All this information is shown on an easy to read LED display.

Virtual Front Panel Software
The 5045 is supplied as standard with Time Electronics’ windows based ‘Virtual Front Panel’ interface. This enables the user to control the instrument via a laptop or PC.

2.2GHz Levelled Sine-Wave Option
For precise bandwidth determination and frequency response analysis the 2.2GHz option is available. The ability to sweep the frequency output from 50MHz to 2.2GHz and adjust the amplitude from 0.5V to 1.5V pk-pk ensures accurate analysis of oscilloscope input amplifiers.

Current Probe Calibration
For calibration of oscilloscope current probes an external adaptor is available. This converts the 5045’s amplitude output to current and covers the range 0.1mA to 100mA pk-pk, 0.2% accuracy, DC or 1kHz.

Rubidium frequency reference
Enhanced timing performance is available by specifying the rubidium high stability frequency reference option (9762). This option achieves timing accuracies required to calibrate high performance timer/counters to 1 part in 10^10.

EasyCal Software – Manage, Automate and Optimise the Calibration Process
To automate the oscilloscope calibration process the 5045 can be controlled using Time Electronics’ EasyCal calibration software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

Technical Specification:

 
STANDARD FEATURES
FUNCTION RANGE SPECIFICATION (± OUTPUT + FLOOR) RESOLUTION
Frequency* 0.1Hz to 10MHz
20MHz to 100MHz
± 0.1ppm
± 20ppm
Fixed Outputs in 1,2,5,10 Sequenced Steps
Period* 10s to 100ns
50ns to 10ns
± 0.1ppm + 30ps
± 20ppm + 50ps
Fixed Outputs in 1,2,5,10 Sequenced Steps
Duty Cycle 100Hz, 1kHz, 10kHz Settable from 0 to 100%
Amplitude DC or 1kHz Square wave 2mV to 200mV
200mV to 20V
20V to 220V
1mV to 200mV (50Ω)
200mV to 2V (50Ω)
± 0.2% + 10μV
± 0.05% + 10μV
± 0.05% + 10μV
± 0.25% + 15μV
± 0.25% + 15μV
10μV
1mV
10mV
100μV
1mV
Fast Rise 10MHz (200mV pk/pk) Rise Time less than 300ps

*Frequency amplitude: 1.5V pk-pk 0.1Hz to 100kHz. 1V pk-pk 200kHz to 100MHz.

2GHz Sweep (9769)

 

– Levelled Sine-Wave
– Settable Amplitudes

50MHz to 199.9MHz: 1%*, 200MHz to 499.9MHz: 2%* , 500MHz to 99.9MHz: 4% , 1GHz to 2.2GHz: 6%
0.5V, 1V, 1.5V pk-pk
50Ω Output
*From 50 to 499.9MHz an additional error of 0.5% of range applies. Frequency accuracy 20ppm.
Rubidium Reference (9762) Rubidium atomic clock 10MHz frequency reference.
Increases accuracy to 1 part in 10*10 (Applies to 10MHz Max output on 5045).
Current Probe Adaptor (9764) Battery powered external adaptor for checking current probes.

 

0.1 to 100mA, 0.2% accuracy.

Full details on the available external options are shown in the Models / Options tab.

Warm up 30 minutes to full accuracy
Settling Time Less than 5 seconds
Standard Interfaces GPIB (IEEE-488), RS-232, USB
Temp Performance Operating: 10 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
Operating Humidity < 80% non-condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 – 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max.
Dimensions W450 x D272 x H152mm (18 x 11 x 7”)
Weight 8.2kg (18lbs)
Country of Origin UK
Supplied With Virtual control software, user manual, RS-232 cable, and USB adaptor/cable
  • Açıklama
    • Product Description:

      Quick and Easy Oscilloscope Calibration to 600MHz
      The 5045 is a versatile, high accuracy calibrator capable of calibrating digital and analogue oscilloscopes, timer/counters, and frequency meters.
      It provides a wide range of outputs for amplitude, frequency, period and bandwidth. Amplitude calibration is achieved by a DC signal or 1kHz square-wave, ranging from 1mV to 220V (2V max for 50 ohm loads). Deviation up to ±9.99% allows fine adjustment of amplitude and direct readout of error.
      Accurate frequencies are generated from a temperature controlled quartz crystal oscillator. Alternatively a 10MHz reference input in can be used. Timing accuracy of 0.1ppm is suitable for most oscilloscopes and timer counters. A precise square-wave output provides a fast rise time of less than 300ps, which allows bandwidth testing up to 600MHz.

      Simple Operation
      Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/-9.99%). All this information is shown on an easy to read LED display.

      Virtual Front Panel Software
      The 5045 is supplied as standard with Time Electronics’ windows based ‘Virtual Front Panel’ interface. This enables the user to control the instrument via a laptop or PC.

      2.2GHz Levelled Sine-Wave Option
      For precise bandwidth determination and frequency response analysis the 2.2GHz option is available. The ability to sweep the frequency output from 50MHz to 2.2GHz and adjust the amplitude from 0.5V to 1.5V pk-pk ensures accurate analysis of oscilloscope input amplifiers.

      Current Probe Calibration
      For calibration of oscilloscope current probes an external adaptor is available. This converts the 5045’s amplitude output to current and covers the range 0.1mA to 100mA pk-pk, 0.2% accuracy, DC or 1kHz.

      Rubidium frequency reference
      Enhanced timing performance is available by specifying the rubidium high stability frequency reference option (9762). This option achieves timing accuracies required to calibrate high performance timer/counters to 1 part in 10^10.

      EasyCal Software – Manage, Automate and Optimise the Calibration Process
      To automate the oscilloscope calibration process the 5045 can be controlled using Time Electronics’ EasyCal calibration software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

      Technical Specification:

       
      STANDARD FEATURES
      FUNCTION RANGE SPECIFICATION (± OUTPUT + FLOOR) RESOLUTION
      Frequency* 0.1Hz to 10MHz
      20MHz to 100MHz
      ± 0.1ppm
      ± 20ppm
      Fixed Outputs in 1,2,5,10 Sequenced Steps
      Period* 10s to 100ns
      50ns to 10ns
      ± 0.1ppm + 30ps
      ± 20ppm + 50ps
      Fixed Outputs in 1,2,5,10 Sequenced Steps
      Duty Cycle 100Hz, 1kHz, 10kHz Settable from 0 to 100%
      Amplitude DC or 1kHz Square wave 2mV to 200mV
      200mV to 20V
      20V to 220V
      1mV to 200mV (50Ω)
      200mV to 2V (50Ω)
      ± 0.2% + 10μV
      ± 0.05% + 10μV
      ± 0.05% + 10μV
      ± 0.25% + 15μV
      ± 0.25% + 15μV
      10μV
      1mV
      10mV
      100μV
      1mV
      Fast Rise 10MHz (200mV pk/pk) Rise Time less than 300ps

      *Frequency amplitude: 1.5V pk-pk 0.1Hz to 100kHz. 1V pk-pk 200kHz to 100MHz.

      2GHz Sweep (9769)

       

      – Levelled Sine-Wave
      – Settable Amplitudes

      50MHz to 199.9MHz: 1%*, 200MHz to 499.9MHz: 2%* , 500MHz to 99.9MHz: 4% , 1GHz to 2.2GHz: 6%
      0.5V, 1V, 1.5V pk-pk
      50Ω Output
      *From 50 to 499.9MHz an additional error of 0.5% of range applies. Frequency accuracy 20ppm.
      Rubidium Reference (9762) Rubidium atomic clock 10MHz frequency reference.
      Increases accuracy to 1 part in 10*10 (Applies to 10MHz Max output on 5045).
      Current Probe Adaptor (9764) Battery powered external adaptor for checking current probes.

       

      0.1 to 100mA, 0.2% accuracy.

      Full details on the available external options are shown in the Models / Options tab.

      Warm up 30 minutes to full accuracy
      Settling Time Less than 5 seconds
      Standard Interfaces GPIB (IEEE-488), RS-232, USB
      Temp Performance Operating: 10 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
      Operating Humidity < 80% non-condensing
      Operating Altitude 0 to 3km. Non operating: 3km to 12km
      Line Power 100 – 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max.
      Dimensions W450 x D272 x H152mm (18 x 11 x 7”)
      Weight 8.2kg (18lbs)
      Country of Origin UK
      Supplied With Virtual control software, user manual, RS-232 cable, and USB adaptor/cable